Request Tech-Sheet No.1926 for Technical Information.
Recommended Operating Temperatures:
100°C, (212°F) to 1.5°C, (35°F)
Maximum Operating Pressure:
20 bar g, (290 psi g)
The new domnick hunter OIL-X EVOLUTION range of compressed air filters has been designed from the outset to meet current and forthcoming requirements for compressed air quality.
Providing an optimal flow path is key to reducing system operating costs.
Using ®rospace technology, domnick hunter has optimised the flow path through the housing and element, significantly reducing air turbulence and pressure losses.
- Stated flows are @ 7 bar g (100 psi g) ANR conditions.
- High efficiency general purpose protection.
- Particle removal of down to 1 micron, including water & oil aerosols.
- Maximum remaining oil aerosol content 0.6mg/m3 a